摘要

目的 研究阿夫唑嗪(alfuzosin,简称AFZ)的电化学行为和电极反应机制,拟定测定AFZ的单扫示波极谱法。方法 采用单扫示波极谱3法、循环伏安法进行研究。结果 在0.01 mol·L-1 KH2PO4K2HPO4(pH7.05)底液中,AFZ在汞电极上有一灵敏的导数还原峰,峰电位Ep=-1.60V(vs.SCE),峰高与AFZ的浓度在1.0×10-7~9.0×10-6范围内呈线性关系(r=0.997 9),检出限为3.0×10-8 mol·L-1。该法应用于片剂中AFZ含量的测定,得到满意结果。结论 实验表明,该体系属两电子还原的不可逆吸附过程。

Abstract

OBJECTIVE To study the electrochemical behavior and reduction mechanism of afluzosin (AFZ) in phosphate buffer solution.A new method for the determination of AFZ was established by single-sweep oscillopolarography.METHODS Single-sweep oscillopolarography,cyclic voltammetry were used.RESULTS In a supporting electrolyte of 0.01 mol·L-1 KH2PO4K2HPO4(pH7.05),a sensitive derivative reduction peak of AFZ was found by single-sweep oscillopolarography.The peak potential was -1.60 V(vs.SCE).The relationship between peak height and the concentration of AFZ was linear from 1.0×10-7 to 9.0×10-6 mol·L-1.The detection limit was 3.0×10-8 mol·L-1.The method was applied to the determination of AFZ in the sample of tablet with satisfactory results.CONCLUSION This indicated an irreversible process with adsorption.

关键词

阿夫唑嗪 / 单扫示波极谱法 / 电化学行为 / 测定

Key words

alfuzosin / oscillopolarography / electrochemical behavior / determination

引用本文

导出引用
曹尔新;曾泳淮;. 阿夫唑嗪的示波极谱法测定及其电化学行为[J]. 中国药学杂志, 2001, 36(11): 763-766
CO Er-xin;ZENG Yong-hui;. Oscillopolarographic determination of alfuzosin and its electrochemical behavior[J]. Chinese Pharmaceutical Journal, 2001, 36(11): 763-766

参考文献

[1]Guinebault P,Broquaire M,Colafranceschi C,et al.High-performance liquid chromatographic determination of alfuzosin in biological fluids with fluorimetric detection and large-volume injection[J].J Chromatogr,1986:353,361. [2]Carlucci G,Giuseppe ED,Mazzeo P.Determination of alfuzosin in human plasma by high-performance liquid chromatography with column-switching[J].J Liq Chromatogr,1994,17(18):3989. [3]Bard AJ,Faulkner LR.Electrochemical Methods[M].New York:John Wiley and Sons,1980:522. [4]Cavalieri LF,Lowy BA.A polarographic study of pyrimidines[J].Arch Biochem Biophys,1952,35:83. [5]Maruyama M,Kazuo MK.Electrochemical behavior of nitrogen heterocycles in N,N-dimethylformamide-water and aqueous buffer[J].J Electroanal Chem,1979,102(2):221.

24

Accesses

0

Citation

Detail

段落导航
相关文章

/