目的 建立一种高灵敏度的检测方法对生物样本(血液、唾液和尿液)中吗啡进行快速定量。方法 采用免疫层析试纸条的反应模式,以稀土元素铕荧光纳米颗粒为标记物,与吗啡单克隆抗体共价偶联,将吗啡抗原和羊抗鼠抗体包被于硝酸纤维素膜上分别作为检测线和质控线,通过竞争性免疫抑制反应原理,结合干式免疫荧光检测仪用于生物样本中吗啡的快速定量。结果 通过优化试验条件后制备得到免疫层析试纸条检测,线性范围在3~3 000 ng·mL-1;精密度和准确度吗啡质控品试验的RSD<10%;与苯丙胺、甲基苯丙胺和氯胺酮等常见毒品和药品均无交叉反应;试纸条在37 ℃,7 d的加速试验中,性能没有明显降低。 结论 本实验初步建立的吗啡免疫荧光层析试纸条定量检测方法具有良好的线性范围和精密度,具有良好的特异性和稳定性。本方法可以快速便捷的对生物样本中吗啡进行定量检测,便于在基层单位推广使用。
Abstract
OBJECTIVE To establish a high sensitivity method for rapid quantitative detection of morphine in the biological samples including serum, saliva and urine. METHODS With the immunochromatographic lateral flow strip as reaction method, the luminescent lanthanide europium nanoparticles covalently conjugated with morphine monoclonal antibody were adopted as reporters. The morphine antigen and goat anti-mouse antibody were coated at the nitrocellulose membrane separately as the test line and control line. The strip based on competitive inhibition immunoassay principle was detected by the fluorescent reader for rapid quantitative detection of morphine in the biological samples. RESULTS After experiment optimization, the improved strip could provide the line range 3-3 000 ng·mL-1; precise quality morphine control materials verified CV<10%. There were no cross reactions with amphetamine, methylamphetamine, ketamine and so on; keep the strips at 37 ℃ for 7 d, the performance of the strips did not decline markedly. CONCLUSION The preliminary established method shows high linearity, precision, specificity and stability. The method could quantitatively detect the morphine in the biological samples in short time. It is supposed to be applied into the grassroots unit.
关键词
吗啡 /
免疫荧光层析法 /
侧向层析试纸条 /
法医毒物分析 /
定量检测
{{custom_keyword}} /
Key words
morphine /
fluorescence immunochromatographic assay /
lateral flow strip /
forensic toxicological analysis /
quantitative detection
{{custom_keyword}} /
中图分类号:
R917
{{custom_clc.code}}
({{custom_clc.text}})
{{custom_sec.title}}
{{custom_sec.title}}
{{custom_sec.content}}
参考文献
[1] CHEN M S, JI Q M, ZHAO F, et al. Development of methamphetamine test strip using luminescent lanthanide nanoparticles[J]. Chin J Forensic Med(中国法医学杂志), 2013, 28 (4):272-274.
[2] ZENG L B, CHEN L K, HU X L, et al. Development of protein chips for quantitative drugs assay[J]. Chin J Forensic Sci(中国司法鉴定), 2012, (1):16-19.
[3] HUA N, ZHANG Y R, SHEN S Y. Development and application of rapid drug detection[J]. World Clin Drugs (世界临床药物), 2016, 37(3):201-203.
[4] FAN X B. Determination of aflatoxin B1 in food by time-resolved fluoroimunoassay[J]. J Food Safety Quality(食品安全质量检测学报), 2017, 8(3):796-802.
[5] GUO M M, ZHOU Y, ZHOU J B, et al. Quantitation of alpha fetoprotein (AFP) in human serum using fluorescence microspheres time-resolved immunochromatographic technology[J]. Immu J(免疫学杂志), 2015, 31(10):897-901.
[6] HU J L, LIU X L, YU D S, et al. Development of fluorescent immunochromatographic strip for detection of cefalexin residue[J]. Chin Pharm J (中国药学杂志), 2014, 49(12):1067-1072.
[7] WANG Y L, LI N, LI Y L, et al. Establishment of quantitative fluorescence immunochromatographic assay detection method for heat shock protein 90α(HSP90α)[J]. Chin Immu J (中国免疫学杂志), 2017, 33(5):712-715.
[8] LI L H, BAI R Y, SUN Y M, et al. Development and application of time-resolved fluroimmunoassay (TR-FIA) for ciprofloxacin determination[J]. Food Sci(食品科学), 2012, 33(8):216-220.
[9] NURALI T, MAO X M, CHE W S, et al. Qualitative and quantitative detection of opioid drugs and their metabolites in the blood and urine by GC and GC-MS methods[J]. J Xinjiang Med Univ(新疆医科大学学报), 2016, 39(7):849-854.
[10] LI K. Fluorescent-Labeled Lateral Flow Test in Quantitative Detection of C-Reaction Protein and Procalcitonin [D]. Guangzhou:South Chin University of Technol, 2016.
[11] ZHU L, ZHOU Y, HUANG B, et al. Establishment of a TRFIA-POCT for FER antibody and its clinical application[J]. Current Immu (现代免疫学), 2016, 36(1):50-53.
[12] GA1333-2017(车辆驾驶人员体内毒品含量阈值与检验)[S]. 2017.
[13] ZHANG X Y, WU C, WEN K, et al. Comparison of fluorescent microspheres and colloidal gold as labels in lateral flow immunochromatographic assays for the detection of T-2 toxin[J]. Molecules,2016, 21(27):1-9.
{{custom_fnGroup.title_cn}}
脚注
{{custom_fn.content}}