基础医学与临床 ›› 2008, Vol. 28 ›› Issue (7): 765-769.

• 技术与方法 • 上一篇    下一篇

MRS无损伤定量测定新西兰兔活体肌肉组织内谷氨酸、谷氨酰胺总浓度的研究

张帆 于健春 樊跃平 何桂珍 胡凌 李晓圳 金征宇   

  1. 北京协和医院外科 北京协和医院外长科 北京协和医院基本外科 中国医学科学院 中国协和医科大学 北京协和医院 北京协和医院放射科 北京协和医院放射科
  • 收稿日期:2006-09-30 修回日期:2007-11-28 出版日期:2008-07-25 发布日期:2008-07-25
  • 通讯作者: 张帆

In vivo Quantitative Measurement of Glutamate & Glutamine in Zelanian Rabbits’ Muscle using MRS ——Research on Feasibility and Accuracy

Fan ZHANG, Yue-ping PAN, Gui-zhen HE, Ling HU, Xiao-zhen LI, Zheng-yu JIN   

  1. PUMC Hospitol ,CAMS&PUMC
  • Received:2006-09-30 Revised:2007-11-28 Online:2008-07-25 Published:2008-07-25
  • Contact: Fan ZHANG,

摘要: 目的 尝试应用磁共振频谱(MRS)方法对新西兰兔活体肌肉组织内总谷氨酸浓度进行测定,并通过肌活检验证其准确性。方法:选取20只健康成年新西兰兔作为样本,使用SS-PRESS序列对其进行MRS采集,记录Glx/TCr的信号强度比;MRS采集后立即对兔子取血并对采集部位进行肌活检,用生化方法测定新西兰兔的血Crn浓度、肌肉 Glx浓度和TCr浓度,使用SPSS统计软件对上述[MRS采集Glx/TCr信号强度比]和[肌肉 Glx/TCr浓度比]、[肌肉 Glx/血Crn浓度比]进行相关性分析,并选用[MRS采集Glx/TCr信号强度比]和[血Crn浓度]来预测[肌肉Glx浓度值]。结果:[MRS采集Glx/TCr峰高比]与[肌活检Glx/血Crn浓度比]的相关系数为0.681。通过线性回归得到公式:[肌肉Glx浓度预测值(umol/g肌肉)]=[MRS采集Glx/TCr峰高比] × [血Crn浓度(mg/dl)]× 28.754-0.631。结论:使用SS-PRESS序列测定新西兰兔肌肉组织,MRS方法检测值与肌活检实测值有明显的正相关性。通过测定新西兰兔血肌酐浓度和进行MRS采集,应用线性回归公式来预测新 西兰兔肌肉组织内总谷氨酸浓度,预测值能反映实际浓度的水平;尽管其精确度难以满足定量分析的要求,但本方法避免了对待测个体的肌活检。

关键词: 磁共振频谱, 肌肉, 谷氨酸, 谷氨酰胺, 定量, 新西兰兔

Abstract: Objective: Try to Use MRS technology to detect Glutamate & Glutamine’s total concentration in Zelanian rabbits’ in vivo muscle. Via biopsy, prove the accuracy of this method. Methods: Select 20 healthy Zelanian rabbits, using SS-PRESS sequence to collect their Signal Ratio of Glx/TCr. After the collection, let blood and do the biopsy of the observed area of the collected muscle tissue immediately. Mensurate the rabbits’ blood Crn concentration, Glx and TCr concentration in muscle. Using SPSS software to research the correlation between the Glx/TCr Signal Ratio and Glx/TCr concentration in muscle, attempt using the MRS Signal Ratio and blood Crn concentration to predict Glx concentration in muscle. Results: The correlation between Glx/TCr Peak Ratio and Glx/Crn ratio is 0.681. We performed a linear regression and got the formula: The predict Value of Glx concentration in muscle (umol/g muscle)= Glx/TCr Peak Ratio × Crn concentration in blood(mg/dl)× 28.754-0.631. Conclusion: Using the MRS method, the detected concentrations of the substances had a strong positive correlation with the biopsy values. Using a linear regression formula to predict the Glx concentration, the results can reflect the level of the true values, though it’s not accurate enough for quantitatively analysis, the new method can avoid biopsy.

Key words: MRS, Muscle, Glutamate, Glutamine, Quantitatively measurement, Zelanian Rabbit