Determination of Octafluoropropane in Canine Exhaled Gas by GC-MS-MS

YNG Ling;CHEN Zhi-ling;LIU Shi-ting;YNG Li

Chinese Pharmaceutical Journal ›› 2007, Vol. 42 ›› Issue (09) : 689-691.

Chinese Pharmaceutical Journal ›› 2007, Vol. 42 ›› Issue (09) : 689-691.
论著

Determination of Octafluoropropane in Canine Exhaled Gas by GC-MS-MS

  • YANG Ling,CHEN Zhi-liang,LIU Shi-ting,YANG Li
Author information +
History +

Abstract

OBJECTIVE To develop a method for the determination of octafluoropropane in canine exhaled gas.To assess the exhaled elimination kinetics of octafluoropropane in anesthetized canines following intravenous administration of octafluoropropane-containing human albumin micropheres.METHODS Octafluoropropane-containing albumin microbubbles at dosages of 0.4,0.8 and 1.2 mL·kg-1 were administered intravenously to anesthetized and ventilated canines.The exhaled air samples were analyzed by gas chromatography-mass spectrum-mass spectrum(GC-MS-MS).The plarmacokinetic parameters were evaluated by WINNOLIN software and noncompartmental analyses.RESULTS The calibration curve of GC-MS-MS was linear within the concentration range of 40.92~16 368 nmol·L-1.In dose of 0.4,0.8 and 1.2 mL·kg-1,cmax were(2.837±0.25),(3.06±0.29) and(13.64±2.99)nmol·L-1 respectively;tmax were(16.67±10.53),(21.66±14.12) and(10±0.00) s,respectively.AUC were(154.19±61.83),(353.77±77.89) and(803.21±335.77) nmol·s·L-1,respectively;MRT were(96.68±1.12),(134.39±38.56) and(91.02±9.27)s,respectively.CONCLUSION The method of GC-MS-MS is accurate ,sensitive,precise and usable for OFP.

Key words

GC-MS-MS / octafluoropropane / ultrasound contrast agent / exhaled gas / concentration / pharmacokinetics

Cite this article

Download Citations
YNG Ling;CHEN Zhi-ling;LIU Shi-ting;YNG Li. Determination of Octafluoropropane in Canine Exhaled Gas by GC-MS-MS [J]. Chinese Pharmaceutical Journal, 2007, 42(09): 689-691

References

[1] HERMAN B,ENINAV S,VERED Z. Feasibility of mitral flow assessment by echo-contrast ultrasound,partⅠ. Determination of the properier of echo-contrast agents[J] .Ultrasound Med Biol,2000,26(5):787-795. [2] CLARK L N,DITTRICH H C. Cardiac image using Optison[J] .Am J Cardiol,2000,86(4A):14-18. [3] OLSZOWSKA W,HLAWATY M,KOSTKIEWICZ M,et al. Role of contrast echocardiography in the improvement of left ventricular endocardial border visualization[J] . Acta Cardiol,2002,57(1):60-61. [4] WONG R F,THOMPSON J T. Prediction of kinetics of disappearance of sulfur hexafluoride and perfluoropropane intrazcular gas bubbles[J] .Ophthalmology,1988,95:609. [5] ANNE L K,PAIGE M M,PAUL A Z,et al. Tissue distribution of 125I-labeled albumin in rats,and whole blood and exhaled elimination kinetics of octafluoropropane in anesthetized canines following intravenous administration of OPTISON(FS069)[J] .Int J Tox,1999,18:49-63. [6] CORREAS J M,MEUTER A R,SINGLAS E,et al. Human pharmacokinetics of a perfluorocarbon ultrasound contrasrt agent evaluated with gas chromatography[J] . Ultrasound Med Biol,2001,27(4):565-570. [7] HUTTER J C,LUU H M,MEHLHAFF P M,et al.Physiologically based pharmacokinetic model for fluorocarbon elimination after the administration of an octafluoropropane-albumin microsphere sonographic contrast agent[J] .J Ultrasound Med,1999,18(2):94.

75

Accesses

0

Citation

Detail

Sections
Recommended

/