Impact Factors on Results of Semi-Quantitative Western Blot in Pharmacological Research
JIANG Chen-chen1, CHENG Jun-jun2, HUANG Meng-hao1, WU Zhou-yi1, LI Jian-rui1, LI Wen-jing1, PENG Zong-gen1*
1. Institute of Medicinal Biotechnology, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing 100050, China; 2. Institute of Materia Medica, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing 100050, China
Abstract��OBJECTIVE To investigate the impact factors of the semi-quantitative Western blot (WB), offering a guidance on research of pharmacological effects of drugs at the level of proteins. METHODS Total proteins were extracted from the Huh7.5 cells infected with hepatitis C virus and quantified with BCA kit, HCV Core protein was chose as target protein, and protein Tubulin or Gapdh, which was encoded by housekeeping gene, as the internal control. By controlling the experimental factors, such as loading sample amount, concentration and the incubation time of first antibodies, and dilutions of chemiluminescent fluid as well, we analyzed those factors how to impact the semi-quantitative results. RESULTS The semi-quantitative results showed that there is a linear relationship between relative intensity of target protein and the amount of total protein at must protein concentration range, beyond which, the rangeability of relative intensity of target protein reduced, even no changes. However, sample volume loaded, or protein selected as internal reference has little influence on the result of semi-quantitative WB. In the context of obtaining high-quality band, concentration and incubation time of antibodies or dilution of chemiluminescent fluid also has no influence on it. Yet, the semi-quantitative WB has certain defects and our results show that the permissible error of semi-quantitative result should be controlled within 15%. CONCLUSION The key impact factor on the result of semi-quantitative WB is the target protein amount of loading. On the premise of obtaining clear and high-quality bands, appropriately selecting loading volume of samples, concentration and incubation time of first antibodies, and dilutions of chemiluminescent fluid is conducive to accomplish experiments without affecting the final results of semi-quantitative WB.
������,�̾���,�����,����һ,���,���ľ�,���ڸ�. ��������ӡ���붨��������ҩ��ѧ�о��е�Ӱ������[J]. �й�ҩѧ��־, 2015, 50(9): 758-762.
JIANG Chen-chen, CHENG Jun-jun, HUANG Meng-hao, WU Zhou-yi, LI Jian-rui, LI Wen-jing, PENG Zong-gen. Impact Factors on Results of Semi-Quantitative Western Blot in Pharmacological Research. Chinese Pharmaceutical Journal, 2015, 50(9): 758-762.
TAYLOR S C, BERKELMAN T, YADAV G, et al. A defined methodology for reliable quantification of Western blot data. Mol Biotechnol, 2013, 55(3):217-226.
[2]
LEWIS C W, TAYLOR R G, KUBARA P M, et al. A western blot assay to measure cyclin dependent kinase activity in cells or in vitro without the use of radioisotopes. FEBS Lett, 2013, 587(18):3089-3095.
[3]
LIU Z Q, MAHMOOD T, YANG P C. Western blot:Technique, theory and trouble shooting. N Am J Med Sci, 2014, 6(3):160.
[4]
PENG Z G, FAN B, DU N N, et al. Small molecular compounds that inhibit hepatitis C virus replication through destabilizing heat shock cognate 70 messenger RNA. Hepatology, 2010, 52(3):845-853.
[5]
NYBO K. Molecular biology techniques Q&A. Western blot:Protein migration. Biotechniques, 2012, 53(1):23-24.
[6]
MAHMOOD T, YANG P C. Western blot:Technique, theory, and trouble shooting. N Am J Med Sci, 2012, 4(9):429-434.
[7]
JOHNSON C A, SHERMAN K, DOYLE C, et al. A comparison of false-negative responses for full threshold and SITA standard perimetry in glaucoma patients and normal observers. J Glaucoma, 2014, 23(5):288-292.
[8]
ROCHA-MARTINS M, NJAINE B, SILVEIRA M S. Avoiding pitfalls of internal controls:Validation of reference genes for analysis by qRT-PCR and Western blot throughout rat retinal development. PLoS One, 2012, 7(8):e43028.
[9]
HE Y, JIANG Y, LU L. Serodiagnosis of grass carp reovirus infection in grass carp Ctenopharyngodon idella by a novel Western blot technique. J Virol Methods, 2013, 194(1-2):14-20. SCHOEN R T. Editorial commentary:Better laboratory testing for Lyme disease:No more Western blot. Clin Infect Dis, 2013, 57(3):341-343.