摘要
目的建立计算机辅助的成像分析平台,分别考察市售的空白丸芯和自制的GBE微丸的圆整度。方法采用计算机辅助的成像分析法。结果空白丸芯和GBE微丸的纵横比(AR)值分别为1.16±0.09,1.14±0.09(n=25),形状因子(eR)值分别为0.56±0.12,0.62±0.14(n=25)。结论该方法能够直观、简便地评价微丸的圆整度,所制备的GBE微丸圆整度较好。
Abstract
OBJECTIVE To establish a computer assistant image system for investigating the pellets sphericity. METHODS The computer assistant image analysis was applied. RESULTS The aspect ratios of the blank and GBE pellets were 1.16±0.09,1.14±0.09(n=25),and the shape factors (eR) were 0.56 ± 0.12,0.62 ±0.14(n=25).CONCLUSION The pellets sphericity can be evaluated directly and conveniently by the computer assistant image analysis. The sphericity of GBE pellets was desirable.
关键词
计算机辅助 /
成像分析 /
微丸 /
圆整度
{{custom_keyword}} /
Key words
computer assistant /
image analysis /
pellet /
sphericity
{{custom_keyword}} /
王俊;周寅;曹志娟;赖顺果;裴元英.
计算机辅助成像分析法在微丸圆整度评价中的应用[J]. 中国药学杂志, 2005, 40(07): 529-531
WNG Jun;ZHOU Yin;CO Zhi-jun;LI Shun-guo;PEI Yun-ying.
Evaluation of pellets sphericity using computer assistant image analysis [J]. Chinese Pharmaceutical Journal, 2005, 40(07): 529-531
{{custom_sec.title}}
{{custom_sec.title}}
{{custom_sec.content}}
参考文献
[1]陆彬.药物新制剂与新技术 [M].北京:人民卫生出版社,1998: 289.
[2]Podczeck F, Rahman SR, Newton JM. Evaluation of a standardised procedure to assess the shape of pellets using image analysis [J].Int J Pharm,1999,192(2):123.
[3]Paterakis PS, Korakianiti ES, Dallas PP,et al. Evaluation and simultaneous optimization of some pellets characteristics using a 3(3) factorial design and the desirability function[J].Int J Pharm,2002, 248(1-2):51.
[4]Podczeck F, Newton JM. A shape factor to characterize the quality of spheroids [J].J Pharm Pharmacol,1994,46(2):82.
[5]Vervaet C, Remon JP. Influence of impeller design, method of screen perforation and perforation geometry on the quality of pellets made by extrusion-shperonisation[J].Int J Pharm,1996,133(1~2):29.
[6]陈挺,陈庆华.盐酸苯丙醇胺微丸的制备工艺研究 [J].中国医药工业杂志,1999,30(8):345.
[7]Podczeck F, Newton JM. The evaluation of a three-dimensional shape factor for the quantitative assessment of the sphericity and surface roughness of pellets[J].Int J Pharm,1995,124(2):253.
[8]胡富强,袁弘,戴缨,等.载体对粉雾剂粉末流动性的影响[J].中国药学杂志,2002,37(2):115.
[9]Andersson M, Holmquist B, Lindquist J,et al. Analysis of film coating thickness and surface area of pharmeutical pellets using fluorescene microscopy and image analysis [J].J Pharm Biomed Anal,2000, 22(2):325.
[10]Larsen CC, Sonnergaard JM, Bertelsen P,et al. Validation of an image analysis method for estimating coating thickness on pellets [J].Eur J Pharm Sci,2003,18(2):191.
{{custom_fnGroup.title_cn}}
脚注
{{custom_fn.content}}