ARCHITECT与TDx测定环孢素A血药浓度相关性研究

李朋梅 刘晓 张镭 赵莉 张相林

中国药学杂志 ›› 2011, Vol. 46 ›› Issue (13) : 1020-1022.

PDF(531 KB)
PDF(531 KB)
中国药学杂志 ›› 2011, Vol. 46 ›› Issue (13) : 1020-1022.
论著

ARCHITECT与TDx测定环孢素A血药浓度相关性研究

  • 李朋梅,刘晓,张镭,赵莉,张相林*
作者信息 +

Correlation between Whole Blood Cyclosporine Concentration Assayed by ARCHITECT and TDx

  • LI Peng-mei,LIU Xiao,ZHANG Lei,ZHAO Li ,ZHANG Xiang-lin*
Author information +
文章历史 +

摘要

目的 研究ARCHITECT与TDx两种方法测定环孢素A(CsA)血药浓度结果相关性。方法 利用ARCHITECT和TDx两种方法同时测定CsA血药浓度,以TDx测定值为X,ARCHITECT测定值为Y,进行线性回归,评价其相关性。结果 ARCHITECT测定值均比TDx低,ρTDx/ρARCHITECT为(1.29±0.22),两种方法的线性相关性较好,回归方程为Y=-26.26+0.993 9X(n=65,r=0.966 5)结论 ARCHITECT测定CsA血药浓度结果较TDx偏低,两种方法相关性好,可以进行方法间切换。

Abstract

OBJECTIVE To evaluate the correlation between the whole blood cyclosporine A (CsA)concentrations by ARCHITECT and TDx monoclonal assay. METHODS A total of 65 samples from renal allograft recipients were determined by ARCHITECT and TDx monoclonal analyzer simultaneously. Regression analyses were performed (ARCHITECT RESULTS as dependant, TDx as independant variable) for the evaluation of correlation. RESULTS ARCHITECT RESULTS were all lower than those from TDx. ρTDx/ρARCHITECT was (1.29±0.22). There existed good correlation with least-squares equation Y=-26.26+0.993 9X(n=65,r=0.966 5). CONCLUSION There is good correlation between ARCHITECT and TDx assay RESULTS. ARCHITECT has achieved a definite improvement in specificity for the parent drug compared with TDx. It can be used for routine monitoring of CsA.

关键词

环孢素A / 血药浓度 / ARCHITECT / TDx

Key words

cyclosporine / whole blood drug concentration / ARCHITECT / TDx

引用本文

导出引用
李朋梅 刘晓 张镭 赵莉 张相林. ARCHITECT与TDx测定环孢素A血药浓度相关性研究[J]. 中国药学杂志, 2011, 46(13): 1020-1022
LI Peng-mei;LIU Xio;ZHNG Lei;ZHO Li;ZHNG Xing-lin. Correlation between Whole Blood Cyclosporine Concentration Assayed by ARCHITECT and TDx[J]. Chinese Pharmaceutical Journal, 2011, 46(13): 1020-1022

参考文献


[1] BOREL J F. Cyclosporin-A-present experimental status[J]. Transplant Proc, 1981, 13(1):344-348.
[2] QUESNIAUX V F J. Immunosuppressants: tools to investigate the physiological role of cytokines[J]. Bioessays, 1993, 15(11):731-739.
[3] CAMPANA C, REGAZZI M B, BUGGIA I, et al. Clinically significant drug interactions with cyclosporin. An update[J]. Clin Parmacokinet, 1996, 30(2):141-179.
[4] WALLEMACQ P, MAINE G T, BERG K, et al. Multisite analytical evaluation of the abbott ARCHITECT cyclosporine assay[J]. Ther Drug Monit, 2010, 32(2):145-151.
[5] MOES D J, PRESS R R, DE FIJTER J W, et al. Liquid chromatography-tandem mass spectrometry outperforms fluorescence polarization immunoassay in monitoring everolimus therapy in renal transplantation[J]. Ther Drug Monit, 2010, 32 (4):413-419.