实时细胞电子分析技术的应用研究进展

严国俊, 裴燕芳, 朱贞宏, , 吴洁颖, 潘金火*

中国药学杂志 ›› 2014, Vol. 49 ›› Issue (3) : 169-173.

PDF(916 KB)
PDF(916 KB)
中国药学杂志 ›› 2014, Vol. 49 ›› Issue (3) : 169-173. DOI: 10.11669/cpj.2014.03.001
综 述

实时细胞电子分析技术的应用研究进展

  • 严国俊1, 裴燕芳1, 朱贞宏2, 3, 吴洁颖3, 潘金火1*
作者信息 +

Research Progress in Application of Real-Time Cell-based Assay (RTCA)

  • YAN Guo-jun1, PEI Yan-fang1 , ZHU Zhen-hong 2, 3, WU Jie-ying3, PAN Jin-huo1*
Author information +
文章历史 +

摘要

目的 综述实时细胞电子分析技术的研究进展, 为中药研究提供参考。 方法 根据近年来国内外相关文献, 对实时细胞电子分析技术的原理、特点及其应用进行归纳总结。 结果与结论 实时细胞电子分析技术是一种无标记、无侵害的实时细胞电子分析方法。综述了实时细胞电子分析技术的应用研究进展, 为其在药学领域进一步应用发展提供参考, 并对其在中药及复方领域的应用前景进行了展望。

Abstract

OBJECTIVE To provide reference for further application of RTCA in the field of TCM(traditional Chinese medicine) development, and summarize the RTCA technology application progress in recent years. METHODS The RTCA technology principles, characteristics and applications are summarized based on referring to the related literature in recent years. RESULTS AND CONCLUSION RTCA is a kind of unmarked, non-invasive real-time cell electronic analysis method. It is recently used in drug screening, toxicology evaluation, cell growth, division and death mechanism research. The dynamic real-time analysis of cell is more and more concerned. The RTCA technology application prospects in the field of traditional Chinese medicine and compound are demonstrated. It is hoped to provide reference for further application of RTCA in the field of pharmaceutical development.

关键词

实时细胞电子分析技术 / 应用进展 / 中药 / 药学

Key words

RTCA / application progress / traditional Chinese medicine / pharmacy

引用本文

导出引用
严国俊, 裴燕芳, 朱贞宏, , 吴洁颖, 潘金火*. 实时细胞电子分析技术的应用研究进展[J]. 中国药学杂志, 2014, 49(3): 169-173 https://doi.org/10.11669/cpj.2014.03.001
YAN Guo-jun, PEI Yan-fang , ZHU Zhen-hong , , WU Jie-ying, PAN Jin-huo*. Research Progress in Application of Real-Time Cell-based Assay (RTCA)[J]. Chinese Pharmaceutical Journal, 2014, 49(3): 169-173 https://doi.org/10.11669/cpj.2014.03.001
中图分类号: R917   

参考文献

GIAEVER I, KEESE C R. Monitoring fibroblast behavior in tissue culture with an applied electric field.Proc Natl Acad Sci USA, 1984, 81(12):3761-3764. ATIENZA J M, ZHU J, WANG X, et al. Dynamic monitoring of cell adhesion and spreading on microelectronic sensor arrays. J Biomol Screen, 2005, 10(8):795-805. KEESE C R, BHAWE K, WEGENER J, et al. Real-time impedance assay to follow invasive activities of metastatic cells in culture. Biotechniques, 2002, 33: 842-850. XIAO C, LACHANCE B, SUNAHARA G, et al. Assessment of cytotoxicity using electric cell-substrate impedance sensing: Concentration and time response function approach. Anal Chem, 2002, 74: 5748-5753. XIAO C, LUONG J H. On-line monitoring of cell growth and cytotoxicity using electric cell-substrate impedance sensing (ECIS). Biotechnol Prog, 2003, 19:1000-1005. SOLLY K, WANG X B. Application of real-time cell electronic sensing (RT-CES) technology to cell-based assays .ASSAY Drug Development Technologies, 2004, 2(4):363-372. ATIENZAR F A, TILMANT K, GERETS H H, et al. The use of real- time cell Analyzer technology in drug discovery: Defining optimal cell culture conditions and assay reproducibility with different adherent cellular models . J Biomol Screen, 2011, 16:575-587. HALAI R, COOPER M A. Using label-free screening technology to improve efficiency in drug discovery . Expert Opin Drug Discov, 2012, 7 (2):123-131. XING J Z, ZHU L J, et al. Dynamic monitoring of cytotoxicity on microelectronic sensors. Chem Res Toxicol, 2005, 2(18): 154-161. ABASSI Y A, JACKSON J A, ZHU J, et al. Labor-free, real-time monitoring or IgE-mediated mast cell activation on microelectronoc cell sensor arrays. J Immunol Methods, 2004, 292: 195-205. SMOUT M J, KOTZE A C, MCCARTHY J S, et al. A novel high throughput assay for anthelmintic drug screening and resistance diagnosis by real-time monitoring of parasite motility. PLoS Negl Trop Dis, 2010, 4(11):885-889. BOITANO S, FLYNN A N, SCHULZ S M, et al. Potent agonists of the protease activated receptor 2(PAR2) . J Med Chem, 2011, 54(5): 1308-1313. NGUEMO F, ARIC T, PFANNKUCHE K, et al. In vitro model for assessing arrhythmogenic properties of drugs based on high-resolution impedance measurements. Cell Physiol Biochem, 2012, 29:819-832. DRR S, LYER S, MANN J, et al. Real-time cell analysis of human cancer cell lines after chemotherapy with functionalized magnetic nanoparticles . Anticancer Resesrch, 2012, 32:1983-1990. XI B, WANG T X, LI N, et al. Functional cardiotoxicity profiling and screening using the xCELLigence RTCA cardio system. J Assoc Lab Automation, 2011, 16(6):415-421. CHEAH S C, APPLETON D R, LEE S T, et al. Panduratin A inhibits the growth of A549 cells through induction of apoptosis and inhibition of NF-KappaB translocation .Molecules, 2011, 16(3):2583-2598. SUN F Y, ZHANG Y Z, TIAN D, et al. Responses after one dose of a monovalent influenza A (H1N1) 2009 inactivated vaccine in Chinese population—A practical observation .Vaccine, 2011, 29(38):6527-6531. ADAMOWICZ J, KLOSKOWSKI T, TWORKIEWICZ J, et al. Urine is a highly cytotoxic agent: Does it influence stem cell therapies in urology. Transpl Proc, 2012, 44(5):1439-1441. QUEREDA J J, MARTNEZ-ALARCN L, MENDOA L, et al. Validation of xCELLigence real-time cell analyzer to assess compatibility in xenotransplantation with pig-to-baboon model. Transpl Proc, 2010, 42(8):3239-3243. FANG Y, YE P F, WANG X B, et al. Real-time monitoring of flavivirus induced cytopathogenesis using cell electric impedance technology . J Virol Methods, 2011, 173(2):251-258. RYDER A B, HUANG Y, LI H J, et al. Assessment of clostridum difficile infections by quantitative detection of tcdb toxin by use of a real-time cell analysis system. J Clin Microbiol, 2010, 48(11): 4129-4134. RAMIS G, MARTNEZ-ALARCN L, MAJADO M J, et alaly. Donor-graft compatibility tests in pig-to-primate xenotransplantation model: Serum versus plasma in real-time cell anzer trials. Transpl Proc, 2011, 43(1):249-253. RAINS G, MARTINEZ-ALARCON L, MAJADO M J, et al. Assessment of in vitro heparin complement regulation capacity during real-time cell analyzer antibody-mediated cytolysis assay: Compatibility studies for pig-to-baboon xenotransplantation. Transpl Proc, 2012, 44(6): 1584-1588. WITTCHEN E S, ELIZABETH HARTNETT M. The small gTpase rap1 is a novel regulator of RPE cell barrier function . IOVS, 2011, 52(10):7455-7463. JIANG A H, GAO H, KELLEY M R, et al. Inhibition of APE1/Ref-1 redox activity with APX3330 blocks retinal angiogenesis in vitro and in vivo . Vision Res, 2011, 51(1):93-100. YU N C, ATIENZA J M, BERNARD J, et al. Real-time monitoring of morphological changes in living cells by electronic cell sensor arrays: An approach to study G protein-coupled receptors . Anal Chem, 2006, 78(1):35-43. FU H Y, FU W Q, SUN M J, et al. Kinetic cellular phenotypic profiling: Prediction, identification, and analysis of bioactive natural products . Anal Chem, 2011, 83(17): 6518-6526.

基金

国家自然科学基金资助项目(81202922);江苏高校优势学科建设工程资助项目(2011ZYX3-004)
PDF(916 KB)

Accesses

Citation

Detail

段落导航
相关文章

/