五氟苯基柱HPLC-PAD法测定硫酸巴龙霉素含量及有关物质

耿月, 朱晓玥, 周小华, 陈舟舟, 朱永强, 袁耀佐

中国药学杂志 ›› 2022, Vol. 57 ›› Issue (16) : 1380-1386.

PDF(1270 KB)
PDF(1270 KB)
中国药学杂志 ›› 2022, Vol. 57 ›› Issue (16) : 1380-1386. DOI: 10.11669/cpj.2022.16.010
论著

五氟苯基柱HPLC-PAD法测定硫酸巴龙霉素含量及有关物质

  • 耿月1,2,3, 朱晓玥2,3, 周小华2,3, 陈舟舟2,3,4, 朱永强1*, 袁耀佐2,3*
作者信息 +

Determination of the Content and Related Substances of Paromomycin Sulfate by HPLC Combined with Pulsed Amperometric Detection Using a Pentafluorophenyl Column

  • GENG Yue1,2,3, ZHU Xiao-yue2,3, ZHOU Xiao-hua2,3, CHEN Zhou-zhou2,3,4, ZHU Yong-qiang1*, YUAN Yao-zuo2,3*
Author information +
文章历史 +

摘要

目的 建立一种用于直接测定硫酸巴龙霉素含量和有关物质的高效液相色谱-脉冲安培电化学检测器(HPLC-PAD)法。方法 采用Agilent Pursuit®PFP(4.6 mm×250 mm,5 μm)色谱柱,以体积分数2.0%三氟乙酸溶液[含0.15%(体积分数)五氟丙酸,用50%氢氧化钠溶液(质量分数)调pH值至3.5]的水溶液为流动相,积分脉冲安培电化学检测器的四电位波形测定硫酸巴龙霉素有关物质。结果 五氟苯基柱比传统的十八烷基硅烷键合硅胶填充色谱柱分离效果更优,代表性样品中分离出21个峰,有巴龙霉素Ⅱ与其同分异构体巴龙霉素Ⅰ和另外的19个有关物质;在0.49~118.30 μg·mL-1内巴龙霉素质量浓度与峰面积呈良好的线性关系(r>0.999 3),检测限(LOD)为0.49 μg·mL-1,定量限(LOQ)为0.99 μg·mL-1,重复性和精密度RSD均小于2.0%。结论 建立的HPLC-PAD方法专属性好、灵敏度高、稳定性强、耐用性好,为巴龙霉素质量控制和工艺优化研究提供了可靠的分析手段。

Abstract

OBJECTIVE To establish a high performance liquid chromatography-pulsed amperometric electrochemical detector(HPLC-PAD) method for the direct determination of paromomycin sulfate raw material. METHODS The separation was performed on Agilent® Pursuit PFP(4.6 mm×250 mm, 5 μm). The mobile phase consisted of 2.0%(V/V) trifluoroacetic acid solution [containing 0.15%(V/V) pentafluoropropionic acid, adjusted to pH 3.5 with 50% sodium hydroxide(W/W)] to determine the substances related to paromomycin sulfate with the four-potential waveform of an integrated pulse amperometric electrochemical detector. RESULTS The established HPLC-PAD method using pentafluorophenyl column, was more suitable for the analysis of polar substances than octadecylsilane bond and silica gel filled column. Twteney-one peaks were separated, including paromomycin Ⅱ and its isomer paromomycin I and 19 other impurities. In the range of 0.49-118.30 μg·mL-1, the concentration of paromomycin showed a good linear relationship with the peak area(r>0.999 3). The limit of detection(LOD) was 0.49 μg·mL-1, the limit of quantitation(LOQ) was 0.99μg·mL-1, and the RSDs of repeatability and precision were less than 2.0%. CONCLUSION The developed HPLC-PAD method has good specificity, sensitivity, stability, and durability, providing a reliable analytical means for the quality control and process optimization of paromomycin.

关键词

硫酸巴龙霉素 / 脉冲安培电化学检测器 / 五氟苯基柱 / 含量测定 / 有关物质

Key words

paromomycin sulfate / high performance liquid chromatography combined with pulsed amperometric detection(HPLC-PAD) / pentafluorophenyl column / content determination / related substance

引用本文

导出引用
耿月, 朱晓玥, 周小华, 陈舟舟, 朱永强, 袁耀佐. 五氟苯基柱HPLC-PAD法测定硫酸巴龙霉素含量及有关物质[J]. 中国药学杂志, 2022, 57(16): 1380-1386 https://doi.org/10.11669/cpj.2022.16.010
GENG Yue, ZHU Xiao-yue, ZHOU Xiao-hua, CHEN Zhou-zhou, ZHU Yong-qiang, YUAN Yao-zuo. Determination of the Content and Related Substances of Paromomycin Sulfate by HPLC Combined with Pulsed Amperometric Detection Using a Pentafluorophenyl Column[J]. Chinese Pharmaceutical Journal, 2022, 57(16): 1380-1386 https://doi.org/10.11669/cpj.2022.16.010
中图分类号: R917   

参考文献

[1] YUAN Y Z, ZHANG M, HU C Q. Advances in the components analysis of aminoglycosides[J].Chin Pharm J(中国药学杂志), 2017, 52(20):1772-1779.
[2] XU H, TANG C L, FAN W Z. Research progress in aminoglycoside antibiotics[J].Chin J New Drugs(中国新药杂志), 2019, 28(15):1828-1835.
[3] AFIF B S, NATHALIE B M, EVELYN G, et al. Topical paromomycin with or without gentamicin for cutaneous leishmaniasis[J]. New Engl J Med,2013, 368(6):524-532.
[4] SHEN L B. Studies on the fragmentation pathway of Paromomycin by ESI MSn[J]. Strait Pharm J(海峡药学), 2013, 25(7):104-106.
[5] FAN M Q, ZHAO M, FAN J. Recent advances on the structure of 30S ribosomal subunit and interaction of 30S ribosome with aminoglycosides[J]. Chin J New Drugs(中国新药杂志), 2006, 15(9):676-682.
[6] IBRANHIM A A, EI-HOUSSENIY G S, ABOSHANAB K M,et al. Paromomycin production from Streptomyces rimosus NRRL 2455: statistical optimization and new synergistic antibiotic combinations against multidrug resistant pathogens[J].BMC Microbiol, 2019, 19(1):18-32.
[7] HANKO V P, ROHRER J S. Determination of neomycin sulfate and impurities using high-performanceanion-exchange chromatography with integrated pulsedamperometricdetection[J]. J Pharm Biomed Anal, 2007, 43(1):131-141.
[8] HUANG M W, HOU Y R, ZHANG Q,et al.Transition of determination method of potency of neomycin sulfate from microbiological assay to HPLC-PAD[J]. Chin Pharm J(中国药学杂志), 2020, 55(2):133-140.
[9] LIU H L, CAO X Y. Determination of ribostamycin sulfate and its related substances by HPLC-ELSD[J]. Chin J Antibiot(中国抗生素杂志), 2010,35(9):684-687.
[10] ZHU X Y, YUAN Y Z, ZHANG M. Determination of the related substances and assay of etimicin sulfate injection by HPLC-PAD[J].Drug Stand China(中国药品标准), 2019,20(6):532-536.
[11] ZHANG Y H, JIANG M H, QIN F, et al. Reflection and outlook on the current analytical methods for aminoglycosides[J].China Pharm(中国药师), 2018,21(6):1082-1089.
[12] YUAN Y Z, ZHANG M, JIN S H. Progress on quality control of aminoglycosides antibiotics[J].Chin J Antibiot(中国抗生素杂志), 2019, 44(11):1244-1255.
[13] LIU Z W, ZHU J P, LIANG Q X, et al. Determination of neomycin B, neamine and related substances in neomycin by HPLC-CAD method[J].Chin J Antibiot(中国抗生素杂志), 2019,44(3):370-375.
[14] CAI Q Y,MOU S F. Optimizing the quadruple-potential waveform for the determination of gentamicin sulfate by high performance liquid chromatography with pulsed electrochemical detection[J].Chin J Chem, 2005, 23(9):1207-1212.
[15] ZHANG Q, HUANG M W, WANG F,et al. Determination of the content and related substances of neomycin sulfate by HPLC combined with pulsed amperometric detection[J].J China Pharm Univ(中国药科大学学报), 2019,50(2):193-199.
[16] YUAN Y Z, CHOPRA S, DENG X L,et al. Analysis of micronomicin by liquid chromatography with pulsed electrochemical detection[J].J Chromatogr A, 2013,1295(5):90-98.
[17] WU Y N, ZHAO W, ZHU X Y,et al. Improved liquid chromatography combined with pulsed electrochemical detection for the analysis of etimicinsulfate[J]. J Sep Sci, 2015,39(8):1471-1479.
[18] YONG Y S, CHONG E T J, CHEN H C, et al.A comparative study of pentafluorophenyl and octadecylsilane columns in high-throughput profiling of biological fluids[J].J Chin Chem Soc, 2017, 64(6):699-710.
[19] YANG S, SADILEK M, LIDSTROM M E. Streamlined pentafluorophenylpropyl column liquid chromatography-tandem quadrupole mass spectrometry and global 13C-labeled internal standards improve performance for quantitative metabolomics in bacteria[J]. J Chromatogr A, 2013,1217(47):7401-7410.
PDF(1270 KB)

353

Accesses

0

Citation

Detail

段落导航
相关文章

/