摘要

基于电化学检测法具有无需衍生、高灵敏度、高选择性以及成本低的特点,高效液相色谱-电化学检测法(HPLC-ED)已经成为药物分析的重要工具。从HPLC-ED技术开始使用40年以来,已有大量相关文章和综述发表。本文将对应用在HPLC中的电化学检测器和检测方法进行回顾,重点介绍HPLC-ED技术在药物分析中的最新研究进展,并讨论这种技术的未来发展趋势。

Abstract

High performance liquid chromatography-electrochemical detection (HPLC-ED)is an important analytical tool for the determination of pharmaceutical drugs since electrochemical detectors provides derivertization-free, sensitive, selective, and low cost detection methods. Numerous papers and reviews have been published since the HPLC-ED techniques were introduced forty years ago. This article will review the electrochemical instruments and detection methods used in HPLC, and focus on recent advances in the analysis of pharmaceutical drugs using HPLC-ED techniques, and discuss the future development trend of the techniques.

关键词

高效液相色谱 / 电化学检测法 / 药物分析 / 流通池 / 脉冲安培检测

Key words

high performance liquid chromatography (HPLC) / electrochemical detection (ED) / drug analysis / flow cell / pulsed amperometric detection(PAD)

引用本文

导出引用
程军, 刘延. 高效液相色谱-电化学检测法在药物分析中的应用[J]. 中国药学杂志, 2017, 52(20): 1753-1771 https://doi.org/10.11669/cpj.2017.20.001
CHENG Jun, LIU Yan. Electrochemical Detection in High Performance Liquid Chromatography for Analysis of Pharmaceutical Drugs[J]. Chinese Pharmaceutical Journal, 2017, 52(20): 1753-1771 https://doi.org/10.11669/cpj.2017.20.001
中图分类号: R917   

参考文献

[1] KISSINGER P T. Amperometric and coulometric detectors for high-performance liquid chromatography [J]. Anal Chem, 1977, 49(4):447-456.
[2] RUCKI R J. Electrochemical detectors for flowing liquid systems [J]. Talanta,1980, 27(2):147-156.
[3] FLANAGAN R J, PERRETT D, WHELPTON R. Electrochemical Detection in HPLC Analysis of Drugs and Poisons[M]. RSC Chromatography Monographs, Roger M Smith (Series Editor), London:Cambridge, 2005.
[4] LACOURSE W R. Pulsed Electrochemical Detection in High Performance Liquid Chromatography[M]. New York :John Wiley & Sons, Inc, USA, 1997.
[5] TULÍK K, PACÁKOVÁ V. Electrochemical detection in HPLC. I. Principles, techniques and instrumentation [J]. Food Nahrung, 1985, 29(5):501-516.
[6] WANG C, XU J, ZHOU G, et al. Electrochemical detection coupled with high-performance liquid chromatography in pharmaceutical and biomedical analysis:a mini review [J]. Comb Chem High Throughput Screen, 2007, 10(7):547-554.
[7] PALMISANO F, ZAMBONIN P G. Electrochemical detection techniques in high performance liquid chromatography:a critical review [J]. Ann Chim, 1984, 74(9-10):633-671.
[8] JOHNSON D C, WEBER S G, BOND A M, et al. Electroanalytical voltammetry in flowing solutions [J]. Anal Chim Acta, 1986, 180:187-250.
[9] TÓTH K, TULÍK K, KUTNER W, et al. Electrochemical detection in liquid flow analytical techniques: characterization and classification(IUPAC technical report)[J]. Pure Appl Chem, 2004, 76(6):1119-1138.
[10] BARD A J, FAULKNER L R. Electrochemical Methods:Fundamentals and Applications[M]. 2nd Edition. New York:John Wiley & Sons, INC, USA, 2001.
[11] WANG J. Analytical Electrochemistry[M]. 3rd edition. New Jersey:Wiley-VCH, John Wiley & Sons, Inc., USA, 2006.
[12] JANDIK P, HADDAD P R, STURROCK P E. Electrochemical detectors for ion chromatographic analysis:a critical review [J]. CRC Cr Rev Anal Chem, 1988, 20(1):1-74.
[13] Electrochemical Detection User's Compendium [Z]. P/N:065340-02, Thermo Scientific, 25, April 2013.
[14] WEBER S G. The dependence of current on flow rate in thin-layer electrochemical detectors used in liquid chromatography [J]. J Electroanal Chem, 1983, 145 (1):1-7.
[15] GUNASINGHAM H, FLEET B. Wall-jet electrode in continuous monitoring voltammetry [J]. Anal Chem,1983, 55(8):1409-1414.
[16] ROE D K. Comparison of amperometric and coulometric electrochemical detectors for HPLC through a figure of merit [J]. Anal Lett, 1983,16(8):613-631.
[17] TULÍK K, PACÁKOVÁ V. Electrochemical detection techniques in high-performance liquid chromatography [J]. J Electroanal Chem Interfacial Electrochem, 1981, 129(1-2):1-24.
[18] CHENG J, JANDIK P. New type of microfabricated carbon electrodes for high-performance liquid chromatography—Amperometric detection of fat-soluble vitamins and antioxidants [J]. J Chromatogr A, 2008, 1198-1199:148-153.
[19] DUBOIS L H, NUZZO R G. Synthesis, structure and properties of model organic surfaces [J]. Ann Phys Chem, 1992, 43:437-463.
[20] JOHNSON D C, LACOURSE W R. Liquid chromatography with pulsed electrochemical detection at gold and platinum electrodes [J]. Anal Chem, 1990, 62(10):589-597.
[21] HUGHES S, MESHI P L, JOHNSON D C. Amperometric detection of simple alcohols in aqueous solutions by application of a triple-pulse potential waveform at platinum electrodes [J]. Anal Chim Acta, 1981, 132:1-10.
[22] ROCKLIN R D, CLARKE A P, WEITZHANDLER M. Improved long-term reproducibility for pulsed amperometric detection of carbohydrates via a new quadruple-potential waveform [J]. Anal Chem, 1998, 70(8):1496-1501.
[23] JOHNSON D C, DOBBERPUHL D, ROBERTS R, et al. Pulsed amperometric detection of carbohydrates amines and sulfur in ion chromatography-the current state of research [J]. J Chromatogr, 1993, 640(1-2):79-96.
[24] HUGHES S, JOHNSON D C. Amperometric detection of simple carbohydrates at platinum electrodes in alkaline solutions by application of a triple-pulse potential waveform [J]. Anal Chim Acta, 1981, 132:11-22.
[25] CHENG J, JANDIK P, LIU X, et al. Pulsed electrochemical detection method [P]. US7566392B2 (US), 2006; WO2007121267A2 (PCT)2007; EP20080886A2 (Europe), 2008; JP2009533690A (Japan), 2009.
[26] Application Brief 130, Rapid Determination of Dopamine and Serotonin in Microdialysis Perfusates with HPLC-ECD [Z]. Thermo Scientific, 2011.
[27] BHATTACHARYYA L. Glyccan Analysis by High Performance Anion Exchange Chromatography with Pulsed Amperometric Detection in Applications of Ion Chromatography for Pharmaceutical and Biological Products [M]. BHATTACHARYYA L, ROHRER J S eds.,New Jersey:John Wiley & Sons, Inc., 2012:323-338.
[28] ROHRER J S. Monosaccharide Analysis Glycoproteins by High Performance Anion-Exchange Chromatography with Pulsed Amperometric Detection in Applications of Ion Chromatography for Pharmaceutical and Biological Products [M]. BHATTACHARYYA L, ROHRER J S eds.,New Jersey:John Wiley & Sons, Inc., 2012:339-350.
[29] JANDIK P, CHENG J. Two-Dimensional Ion Chromatography for Simultaneous Determination of Amino Acids and Carbohydrates in Applications of Ion Chromatography for Pharmaceutical and Biological Products [M]. BHATTACHARYYA L, ROHRER J S eds., New Jersey:John Wiley & Sons, Inc., 2012:351-364.
[30] GREY C. Monitoring Protein N-Glycosylation Consistency Using HPAEC-PAD in Applications of Ion Chromatography for Pharmaceutical and Biological Products [M]. BHATTACHARYYA L, ROHRER J S eds., New Jersey:John Wiley & Sons, Inc., 2012:365-378.
[31] BRUGGINK C. Oligosaccharide Analysis by High-Performance Anion-Exchange Chromatography Hyphenated to Integrated Pulsed Amperometric Detection and On-line Ion-trap Mass-Spectrometry in Applications of Ion Chromatography for Pharmaceutical and Biological Products [M]. BHATTACHARYYA L, ROHRER J S eds., New Jersey:John Wiley & Sons, Inc., 2012:379-391.
[32] RICCI S, FABBRI B,GIANNINI S, et al. High-Performance Anion-Exchange Chromatography with Pulsed Amperometric Detection (HPAEC-PAD) Analysis of GBS Glycoconjugated Vaccines:From Fermentation to Final Product in Applications of Ion Chromatography for Pharmaceutical and Biological Products [M]. BHATTACHARYYA L, ROHRER J S eds., New Jersey:John Wiley & Sons, Inc., 2012:435-447.
[33] CAI Y, CAI Y, CHENG J, et al. Comparative study on the analytical performance of three waveforms for the determination of several aminoglycoside antibiotics with high performance liquid chromatography using amperometric detection [J]. J Chromatogr A, 2005, 1085(1):124-130.
[34] ZAWILLA N H, DIANA J, HOOGMARTENS J, et al. Analysis of neomycin using an improved liquid chromatographic method combined with pulsed electrochemical detection [J]. J Chromatogr B, 2006, 833(2):191-198.
[35] ZAWILLA N H, LI B, HOOGMARTENS J, et al. Improved reversed-phase liquid chromatographic method combined with pulsed electrochemical detection for the analysis of amikacin [J]. J Pharm Biomed Anal, 2007, 43(1):168-173.
[36] HANKO V P, ROHRER J S. Determination of tobramycin and impurities using high-performance anion-exchange chromatography with integrated pulsed amperometric detection [J]. J Pharm Biomed Anal, 2006, 40(4):1006-1012.
[37] HANKO V P, ROHRER J S, LIU H H, et al. Identification of tobramycin impurities for quality control process monitoring using high-performance anion-exchange chromatography with integrated pulsed amperometric detection [J]. J Pharm Biomed Anal, 2008, 47(4-5):828-833.
[38] HANKO V P, ROHRER J S. Determination of neomycin sulfate and impurities using high-performance anion-exchange chromatography with integrated pulsed amperometric detection [J]. J Pharm Biomed Anal, 2007, 43(1):131-141.
[39] CHOPRA S, VANDERHEYDEN G, HOOGMARTENS J, et al. Comparative study on the analytical performance of different detectors for the liquid chromatographic analysis of tobramycin [J]. J Pharm Biomed Anal, 2010, 53(2):151-157.
[40] WU Y, ZHAO W, ZHU X, et al. Improved liquid chromatography combined with pulsed electrochemical detection for the analysis of etimicin sulfate [J]. J Sep Sci, 2016, 39(8):1471-1479.
[41] MANYANGA V, GRISHINA O, YUN Z, et al. Comparison of liquid chromatographic methods with direct detection for the analysis of gentamicin [J]. J Pharm Biomed Anal, 2007, 45(2):257-262.
[42] YUAN Y, CHOPRA S, DENG X, et al. Analysis of micronomicin by liquid chromatography with pulsed electrochemical detection [J]. J Chromatogr A, 2013, 1295:90-98.
[43] ZAATER M F, TAHBOUB Y R, GHANEM E. Determination and stability assessment of clarithromycin in human plasma using RP-LC with electrochemical detection [J]. J Chromatogr Sci,2012, 50(9):763-768.
[44] MOCHIZUKI N, SUKA E, MATSUMOTO K, et al. Liquid chromatographic method for the determination of sirolimus in blood using electrochemical detection quantitation of sirolimus by HPLC-ECD in human blood [J]. Biomed Chromatogr, 2009, 23(3):267-272.
[45] CAI Y, CAI Y, SHI Y, et al. Optimizing the integrated pulsed amperometric multicycle step waveform for the determination of tetracyclines [J]. J Chromatogr A, 2005, 1085(1):98-103.
[46] CASELLA I G, PICERNO F. Determination of tetracycline residues by liquid chromatography coupled with electrochemical detection and solid phase extraction [J]. J Agric Food Chem, 2009, 57(19):8735-8741.
[47] CANNAZZA G, DI STEFANO A, MOSCIATTI B, et al. Detection of levodopa, dopamine and its metabolites in rat striatum dialysates following peripheral administration of L-DOPA prodrugs by mean of HPLC-EC [J]. J Pharm Biomed Anal, 2005, 36(5):1079-1084.
[48] LIN L, QIU P, YANG L, et al. Determination of dopamine in rat striatum by microdialysis and high-performance liquid chromatography with electrochemical detection on a functionalized multi-wall carbon nanotube electrode [J]. Anal Bioanal Chem, 2006, 384(6):1308-1313.
[49] CHAU R M W, PATEL B A. Determination of serotonin, melatonin and metabolites in gastrointestinal tissue using high-performance liquid chromatography with electrochemical detection determination of serotonin, melatonin and metabolites in gastrointestinal tissue [J]. Biomed Chromatogr, 2009, 23(2):175-181.
[50] PERATI P R, CHENG J, JANDIK P, et al. Disposable carbon electrodes for liquid chromatographic detection of catecholamines in blood plasma samples [J]. Electroanalysis, 2010, 22(3):325-332.
[51] PARROT S, NEUZERET P C, DENOROY L. A rapid and sensitive method for the analysis of brain monoamine neurotransmitters using ultra-fast liquid chromatography coupled to electrochemical detection [J]. J Chromatogr B, 2011, 879(32):3871-3878.
[52] OPPOLZER D, MORENO I, DA FONSECA B, et al. Analytical approach to determine biogenic amines in urine using microextraction in packed syringe and liquid chromatography coupled to electrochemical detection [J]. Biomed Chromatogr, 2013, 27(5):608-614.
[53] HUANG Y B, WU P C, HSU M W, et al. Highly sensitive analysis of the anti-tumor agent 1-[4-(furo[2,3-b]-quinolin-4-ylamino)phenyl]ethanone in rat plasma by high-performance liquid chromatography using electrochemical detection [J]. J Pharm Biomed Anal, 2005, 38(3):551-555.
[54] XIA J, KOTANI A, HAKAMATA H, et al. Determination of hesperidin in Pericarpium Citri Reticulatae by semi-micro HPLC with electrochemical detection [J]. J Pharm Biomed Anal, 2006, 41(4):1401-1405.
[55] KHAN A, IQBAL Z, WATSON D G, et al. Simultaneous determination of lipoic acid (LA)and dihydrolipoic acid (DHLA)in human plasma using high-performance liquid chromatography coupled with electrochemical detection [J]. J Chromatogr B, 2011, 879(20):1725-1731.
[56] CAMPOS P M, GARCIA PRAC F S, BENTLEY M V L B. Quantification of lipoic acid from skin samples by HPLC using ultraviolet, electrochemical and evaporative light scattering detectors [J]. J Chromatogr B, 2016, 1019:66-71.
[57] FARN S S, YEH Y H, LIN W J, et al. Development and validation of 2-deoxy-2-chloro-o-glucose impurity analysis in [18F]FDG by three potential-time waveforms of high-performance liquid chromatography/pulsed amperometric detection [J]. Nucl Med Biol, 2009, 36(2):225-231.
[58] SUZUKI K, KATAYAMA M, TAKAMATSU K, et al. Improvement of sensitivity and selectivity of high-performance liquid chromatography for anti-retroviral drugs (non-reverse transcriptase inhibitors)by diamond-electrode electrochemical and fluorescence detection [J]. J Chromatogr A, 2009, 1216(15):3117-3121.
[59] LAI C S, NAIR N K, MUNIANDY A, et al. Validation of high performance liquid chromatography-electrochemical detection methods with simultaneous extraction procedure for the determination of artesunate, dihydroartemisinin, amodiaquine and desethylamodiaquine in human plasma for application in clinical pharmacological studies of artesunate-amodiaquine drug combination [J]. J Chromatogr B, 2009, 877(5-6):558-562.
[60] LIU L, LI S, CHEN Z. Simultaneous determination of tetrandrine and fangchinoline in herbal medicine Stephania tetrandra S. Moore by liquid chromatography with electrochemical detection [J]. J Pharm Biomed Anal, 2012, 61:252-255.
[61] LIU L, CHEN Z. Analysis of four alkaloids of Coptis chinensis in rat plasma by high performance liquid chromatography with electrochemical detection [J]. Anal Chim Acta, 2012, 737:99-104.
[62] LI Y, WANG F, CHEN Z. Determination of bavachin and isobavachalcone in Fructus Psoraleae by high-performance liquid chromatography with electrochemical detection [J]. J Sep Sci, 2011, 34(5):514-519.
[63] SARACINO M A, GANDOLFI O, DALL'OLIO R, et al. Determination of olanzapine in rat brain using liquid chromatography with coulometric detection and a rapid solid-phase extraction procedure [J]. J Chromatogr A, 2006, 1122(1-2):21-27.
[64] LOCATELLI I, MRHAR A, GRABNAR I. Simultaneous determination of risperidone and 9-hydroxyrisperidone enantiomers in human blood plasma by liquid chromatography with electrochemical detection [J]. J Pharm Biomed Anal, 2009, 50(5):905-910.
[65] KOTANI A, KOTANI T, ISHII N, et al. The effect of hyperglycemia on the pharmacokinetics of valproic acid, studied by high-performance liquid chromatography with electrochemical detection [J]. J Pharm Biomed Anal, 2014, 97:47-53.
[66] HONEYCHURCH K C, SMITH G C, HART J P. Voltammetric behavior of nitrazepam and its determination in serum using liquid chromatography with redox mode dual-electrode detection [J]. Anal Chem, 2006, 78(2):416-423.
[67] GOULAY-DUFAŸ DO B, HOANG L, et al. Determination of a 3,4-diaminopyridine in plasma by liquid chromatography with electrochemical detection using solid-phase extraction [J]. J Chromatogr B, 2004, 805(2):261-266.
[68] ZHANG W, WAN F, ZHU W, et al. Determination of glutathione and glutathione disulfide in hepatocytes by liquid chromatography with an electrode modified with functionalized carbon nanotubes [J]. J Chromatogr B, 2005, 818(2):227-232.
[69] BARTOŠOVÁ Z, JIROVSKY D, HORNA A. High-performance liquid chromatographic method with amperometric detection employing boron-doped diamond electrode for the determination of sildenafil, vardenafil and their main metabolites in plasma [J]. J Chromatogr A, 2011, 1218(44):7996-8001.
[70] SARACINO M A, CANNISTRACI C, BUGAMELLI F, et al. A novel HPLC-electrochemical detection approach for the determination of D-penicillamine in skin specimens [J]. Talanta, 2013, 103:355-360.
[71] KARADAS-BAKIRHAN N, SARAKBI A, VANDEPUT M, et al. Liquid chromatography with amperometric detection at a silver based detector for the determination of thiocompounds:application to the assay of thiopurine antimetabolites in urine [J]. Anal Chem, 2015, 87(13):6730-6735.
[72] BOSE D, DURGBANSHI A, MARTINAVARRO-DOMÍNGUEZ A, et al. Rapid determination of acetaminophen in physiological fluids by liquid chromatography using SDS mobile phase and ED detection [J]. J Chromatogr Sci, 2005, 43(6):313-318.
[73] SUZUKI N, MIYASHITA N, KOTANI A, et al. Determination of troglitazone stereoisomers in rat plasma using semi-micro HPLC with electrochemical detection [J]. J Pharm Biomed Anal, 2005, 38(1):155-161.
[74] PALUMBO G, BACCHI S, PRIMAVERA L, et al. A validated HPLC method with electrochemical detection for simultaneous assay of 5-aminosalicylic acid and its metabolite in human plasma [J]. Biomed Chromatogr, 2005, 19(5):350-354.
[75] MASHAYEKHI S O, GHANDFOROUSH-SATTARI M, HAIN R D W. Rapid and sensitive quantitation of morphine using HPLC with electrochemical detection [J]. J Clin Pharm Ther, 2008, 33(4):419-427.
[76] LISI T L, SLUKA K A. A new electrochemical HPLC method for analysis of enkephalins and endomorphins [J]. J Neurosci Methods, 2006, 150(1):74-79.
[77] CHMIELEWSKA A, KONIECZNA L, PLENIS A, et al. Determination of diclofenac in plasma by high-performance liquid chromatography with electrochemical detection [J]. Biomed Chromatogr, 2006, 20(1):119-124.
[78] ZHANG X Z, GAN Y R, ZHAO F N. Determination of residual clenbuterol in pork meat and liver by HPLC with electrochemical detection [J]. Acta Pharm Sin, 2004, 39(4):276-280.
[79] ZHANG X Z, GAN Y R, ZHAO F N. Determination of salbutamol in human plasma and urine by high-performance liquid chromatography with a coulometric electrode array system [J]. J Chromatogr Sci, 2004, 42(5):263-267.
[80] MANCINI F, BOLOGNESI M L, MELCHIORRE C, et al. Monolithic stationary phase coupled with coulometric detection:development of an ion-pair HPLC method for the analysis of quinone-bearing compounds [J]. J Sep Sci, 2007, 30(17):2935-2942.
[81] HANKO V P, ROHRER J S. Ion Chromatography Analysis of Aminoglycoside Antibiotics in Applications of Ion Chromatography for Pharmaceutical and Biological Products [M]. BHATTACHARYYA L, ROHRER J S, eds.,New Jersey:John Wiley & Sons, Inc., 2012:175-192.
[82] POLTA J A, JOHNSON D C, MERKEL K E. Liquid chromatographic separation of aminoglycosides with pulsed electrochemical detection [J]. J Chromatogr, 1985, 324:406-414.
[83] STATLER J. Determination of tobramycin using high-performance liquid chromatography with pulsed amperometric detection [J]. J Chromatogr, 1990, 527(1):244-246.
[84] ADAMS E, SCHEPERS R, ROETS E, et al. Determination of neomycin sulfate by liquid chromatography with pulsed electrochemical detection [J]. J Chromatogr A, 1996, 741(1):233-240.
[85] ADAMS E, DALLE J, DE BIE E, et al. Determination of kanomycin sulfate by liquid chromatography with pulsed electrochemical detection [J]. J Chromatogr A, 1997, 766(1-2):133-139.
[86] CHENG J, JANDIK P, LIU X. Improving reliability and sensitivity of a chromatographic determination of netilmicin [D]. The 56th Pittsburgh Conference, Orlando, Florida, USA, 2005.
[87] CLARKE A P, JANDIK P, ROCKLIN R D, et al. Integrated amperometry waveform for the direct, sensitive detection of amino acids, and amino sugars following anion-exchange chromatography [J]. Anal Chem, 1999, 71(14):2772-2781.
[88] CAI Y, CHENG J, MOU S, et al. Improved sensitivity and robustness of chromatographic assays for netilmicin [J]. Pharm Forum, 2004, 30(4):1501-1507.
[89] Ch. P(2015)[S]. 2015:1343-1344.
[90] GONZÁLEZ D L, HUEBRA M J, VINCENT U. Analysis of macrolide antibiotics by liquid chromatography [J]. J Pharm Biomed Anal, 2005, 39(3-4):376-398.
[91] BILLEDEAU S M, HEINZE T M, SIITONEN P H. Liquid chromatography analysis of erythromycin A in salmon tissue by electrochemical detection with confirmation by electrospray ionization mass spectrometry [J]. J Agric Food Chem, 2003, 51(6):1534-1538.
[92] SOUTHWICK S M, PAIGE S, MORGAN C A, et al. Neurotransmitter alterations in PTSD:catecholamines and serotonin [J]. Semin Clin Neuropsychiatry, 1999, 4(4):242-248.
[93] TAN K R, RUDOLPH U, LÜSCHER C. Hooked on benzodiazepines:GABAA receptor subtypes and addiction [J]. Trends Neurosci, 2011, 34(4):188-197.
[94] KAHN C M, LINE S, AIELLO S E. The Merck Veterinary Manual [M]. 9th Edition. New York:John Wiley & Sons, Inc., 2005.
[95] HONEYCHURCH K C, HART J P. Electrochemical detection of benzodiazepines, following liquid chromatography, for applications in pharmaceutical, biomedical and forensic investigations [J]. Insci J, 2014, 4(1):1-18.
[96] HONEYCHURCH K. Review:the application of liquid chromatography electrochemical detection for the determination of drugs of abuse [J]. Separations, 2016, 3(4):28-56.
[97] MOLINA A, GONZALEZ J. Pulse Voltammetry in Physical Electrochemistry and Electroanalysis Theory and Applications[M]. New York:Springer International Publishing, 2016.
[98] MACCREHAN W A, DURST R A. Measurement of organomercury species in biological samples by liquid chromatography with differential pulse electrochemical detection [J]. Anal Chem, 1978, 50(14):2108-2112.
[99] GOYAL R N, BACHHETI N, TYAGI A, et al. Differential pulse voltammetri determination of methylprednisolone in pharmaceuticals and human biological fluids [J]. Anal Chim Acta, 2007, 605(1):34-40.
[100] EL-SHAL M A. Electrochemical studies for the determination of quetiapine fumarate and olanzapine antipsychotic drugs [J]. Adv Pharm Bull, 2013, 3(2):339-344.
[101] REIM R E. Postcolumn deoxygenator for liquid chromatography with reductive electrochemical detection [J]. Anal Chem, 1983, 55(7):1188-1191.
[102] CHENG J, LIU Y. Method of measuring an analyte with a reductive detection waveform [P]. US Patent, submitted 2017.
[103] MALONE M, WEBER P L, SMYTH M R, et al. Reductive electrochemical detection for capillary electrophoresis [J]. Anal Chem, 1994, 66(21):3782-3787.
[104] WILHELM M, BATTISTA H J, OBENDORF D. HPLC with simultaneous UV and reductive electrochemical detection at the hanging mercury drop electrode:a highly sensitive and selective tool for the determination of benzodiazepines in forensic samples [J]. J Anal Toxicol, 2001,25(4): 250-257.
[105] ACWORTH I N, NAOI M, PARVEZ H, et al. Coulometric Electrode Array Detectors for HPLC [M]. Progress in HPLC-HPCE Volume 6, VSP BV, Otrecht, The Netherlands, 1997.
[106] ACWORTH I, ULLUCCI P, WARASKA J, et al. Application of HPLC with photodiode array and coulometric electrochemical array detection to the study of natural products, botanicals, and mammalian tissues:from targeted analyses to metabolomics [Z]. Thermo Fisher Scientific, Application Note, 2011.
[107] ACWORTH I N, WARASKA J, GAMACHE P H. The coulometric electrode array for use in HPLC analysis. Part 2:applications overview [J]. Amer Lab,1997, 11(1):25-32.
[108] BUCHANAN E, BACON J. Continuous monitoring of ion-exchange column effluents with square-wave polarography [J]. Anal Chem, 1967, 39(6):615-620.
[109] SAMUELSON R, O'DEA J, OSTERYOUNG J. Rapid scan square wave voltammetric detector for high-performance liquid chromatography [J]. Anal Chem, 1980, 52(13):2215-2216.
[110] REARDON P, O'BRIEN G, STURROCK P A. A swept-potential electrochemical detector for flow streams [J]. Anal Chim Acta, 1984, 162:175-187.
[111] STURROCK P A, O' BRIEN G. Voltammetry with programmed baseline compensation [J]. Anal Chim Acta, 1996, 324(2-3):135-145.
[112] JOHNSON D C, LACOURSE W R. Pulsed electrochemical detection at noble metal electrodes in liquid chromatography [J]. Electroanalysis, 1992, 4(4):367-380.
[113] STEFANI S, SEEBER R. Theory of staircase voltammetry for simple electrode reactions [J]. Anal Chem, 1982, 54(14):2524-2530.
[114] KENNEDY R T, JORGENSON J W. Quantitative analysis of individual neurons by open tubular liquid chromatography with voltammetric detection [J]. Anal Chem, 1989, 61(5):436-441.
[115] OWENS D S, JOHNSON C M, STURROCK P E, et al. Swept-potential oxidative detection in flow streams [J]. Anal Chim Acta, 1987, 197:249-256.
[116] SCANLON J J, FLAQUER P A, ROBINSON G W, et al. High-performance liquid chromatography of nitrophenols with a swept-potential electrochemical detector [J]. Anal Chim Acta, 1984, 158:169-177.
[117] JANDIK P, CLARKE A P, AVDALOVIC N, et al. Analyzing mixtures of amino acids and carbohydrates using bi-modal integrated amperometric detection [J]. J Chromatogr B, 1999, 732(1):193-201.
[118] Thermo Fisher Scientific, Peak Identification and Estimation of percent Purity Using HPAE with 3-D Amperometry[Z]. Technical Note 63.
[119] CHENG J, JANDIK P, POHL C. Optimizing 3D Amperometry for Analyte Identification in HPLC [R]. 18th International Ion Chromatography Symposium, Montreal, Quebec, Canada, 2005.
[120] BAUMANN A, KARST U. Online electrochemistry/mass spectrometry in drug metabolism studies:principles and applications [J]. Expert Opin Drug Metab Toxicol, 2010, 6(6):715-731.
[121] FABER H, VOGEL M, KARST U, Electrochemistry/mass spectrometry as a tool in metabolism[J]. Anal Chim Acta, 2014, 834:9-21.
[122] ODIJK M, OLTHUIS W, VAN DEN BERG A, et al. Improved conversion rates in drug screening applications using miniaturized electrochemical cells with frit channels [J]. Anal Chem, 2012, 84(21):9176-9183.
[123] SZABO Z, THAYER J R, AGROSKIN Y, et al. In-depth analyses of native N-linked glycans facilitated by high-performance anion exchange chromatography-pulsed amperometric detection coupled to mass spectrometry [J]. Anal Bioanal Chem, 2017, 409(12):3089-3101.
[124] GAMACHE P, ACWORTH I. Measurement of environmental estrogens in water using a gradient HPLC-EC-UV Method [Z]. Thermo Fisher Scientific, Application Note, 2016.
[125] KATAYAMA M, TAKAMATSU K, KANEKO S, et al. HPLC for stress-free screening of potential prostate cancer marker catechol estrogens in urine using a diamond-electrode electrochemical and a fluorescence detector [J]. J Sep Sci, 2007, 30 (14):2279-2285.
[126] CHENG J, LIU Y. Simultaneous determination of carbohydrates and organic acids with high performance anion-exchange chromatography, and pulsed amperometric detection and conductivity detection [Z]. Unpublished data, 2015.
[127] CHENG J, JANDIK P, POHL C. Electrochemical detection cell for liquid chromatography system [P]. WO2011100248A1 (PCT), 2011; EP2534727A4 (Europe), 2012; CN102834964A (China), 2012; US8342007B2 (US), 2013 and JP2013519881A (Japan), 2013.
[128] FORSTER R J. Microelectrodes:new dimensions in electrochemistry [J]. Chem Soc Rev, 1994, 23(4):289-297.
[129] FEDOROWSKI J, LACOURSE W R. A review of pulsed electrochemical detection following liquid chromatography and capillary electrophoresis [J]. Anal Chim Acta, 2015, 861:1-11.
[130] PAULUS A, KLOCKOW A. Detection of carbohydrates in capillary electrophoresis [J]. J Chromatogr A, 1996, 720(1-2):353-376.
[131] BALDWIN R P. Recent advances in electrochemical detection in capillary electrophoresis [J]. Electrophoresis, 2000, 21(18):4017-4028.
[132] GARCIA C D, HENRY C S. Coupling capillary electrophoresis and pulsed electrochemical detection [J]. Electroanalysis, 2005, 17(13):1125-1131.
[133] LACOURSE W R, OWENS G S. Pulsed electrochemical detection of thiocompounds following microchromatographic separations [J]. Anal Chim Acta, 1995, 307(2-3):301-319.
[134] TABEI H, TAKAHASHI M, HOSHINO S, et al. Subfemtomole detection of catecholamine with interdigitated array carbon microelectrodes in HPLC [J]. Anal Chem, 1994, 66 (20):3500-3502.
[135] BARTOSOVA Z, JIROVSKY D, RIMAN D, et al. HPLC-ED of low-molecular weight brominated phenols and tetrabromobisphenol A using pretreated carbon fiber microelectrode [J]. Talanta, 2014, 122:115-121.
[136] CHENG J, JANDIK P, AVDALOVIC N. Development and characterization of microfabricated disposable gold working electrodes for high-performance ion chromatography and integrated pulsed amperometric detection[J]. Anal Chem, 2003, 75(3):572-579.
[137] CHENG J, JANDIK P, AVDALOVIC N. Pulsed amperometric detection of sulfide, cyanide, iodide, thiosulfate, bromide and thiocyanate with microfabricated disposable silver working electrodes in ion chromatography [J]. Anal Chim Acta, 2005, 536(1-2):267-274.
[138] LIANG L, CAI Y, MOU S, et al. Comparisons of disposable and conventional silver working electrode for the determination of iodide using high-performance anion-exchange chromatography with pulsed amperometric detection [J]. J Chromatogr A, 2005, 1085(1):37-41.
[139] CHENG J, JANDIK P, LIU X, et al. Pulsed amperometric detection waveform with disposable thin-film platinum working electrodes in high performance liquid chromatography [J]. J Electroanal Chem, 2007, 608(2):117-124.
[140] CHENG J, JANDIK P. Electroactivity of nitriles on platinum electrodes and its use in chromatographic detection [J]. Electrochem Commun, 2009, 11(8):1615-1617.
[141] HERNÁNDEZ-BORGES J, ATURKI Z, ROCCO A, et al. Recent applications in nanoliquid chromatography [J]. J Sep Sci, 2007, 30 (11):1589-1610.
[142] VICKERS J A, HENRY C S. Simplified current decoupler for microchip capillary electrophoresis with electrochemical and pulsed amperometric detection [J]. Electrophoresis, 2005, 26(24):4641-4647.
[143] MORA M F, DING Y, MEJIA D E, et al. Application of microchip-capillary electrophoresis and pulsed electrochemical detection to the analysis of biologically relevant phenolic compounds [J]. J Cap Elec Microchip Tech, 2007, 1(2):7-18.
[144] MATYSIK F M. Advances in amperometric and conductometric detection in capillary and chip-based electrophoresis [J]. Microchim Acta, 2008, 160(1):1-14.
[145] EIJKEL J. Chip-based HPLC:the quest for the perfect column [J]. Lab Chip, 2007, 7:815-817.
[146] ISHIDA A, FUJIMOTO T, YOKOGAWA S, et al. Portable liquid chromatography system based on battery-powered electroosomotic pump and microchip with packed column and electrochemical detector [R]. 16th International Conference on Miniaturized Systems for Chemistry and Life Sciences, Okinawa, Japan, 2012, 1183-1185.
[147] ISHIDA A, NATSUME M, KAMIDATE T. Microchip reversed-phase liquid chromatography with packed column and electrochemical flow cell using polystyrene/poly(dimethylsiloxane)[J]. J Chromatogr A, 2008, 1213(20):209-217.
[148] MUNSHI A S, MARTIN R S. Microchip-based electrochemical detection using a 3-D printed wall-jet electrode device [J]. Analyst, 2016, 141(3):862-869.
PDF(1674 KB)

Accesses

Citation

Detail

段落导航
相关文章

/